← Back

ZOLUXPRO · CNC

Fresh coolant mixture

Enter your known values. Results and formulas update instantly.

CONCENTRATE + WATER
Concentrate1.2 LWater18.8 LConcentrate1,200 mL
Vc = V × C / 100; Vw = V − Vc

Interpretation and limits

Ideal volume balance for a fresh mixture, not top-up or correction of an existing sump. Check the supplier’s range, water, equipment and mixing order. For Blaser emulsions the manufacturer specifies slowly adding concentrate to stirred water. Verify concentration with the product factor. The 0/100% endpoints are mathematical limits only.

Example: 20 L at 6% = 1.2 L concentrate and 18.8 L water. This is not a universal recommended concentration.

Blaser Swisslube · FAQ